The battery in the Programmable Logic Controller (PLC) that runs your automated equipment should be changed on a regular basis to prevent setup data from being lost. The PLC's in Gruber equipment, except for the Ultra line of Autocaster casting machines use a battery to prevent the loss of changeable data such as recipe's, totals, calibration factors during times without power.
Although the battery may last 2-3 years under normal use with power off only nights and weekends we recommend replacing the battery annually to be sure it's ready when you need it. A good practice is to replace it on your birthday, anniversary, or other memorable date.
See the FAQ How Do I Replace The PLC Battery? for detailed replacement instructions.
Common Replacement Battery Order Numbers: 161084 for S7-314IFM PLC typically used for Autocaster RC. 180384 for S7-22x PLC's typically used on Autocaster Economizers and most Batchmasters. 180385 for S7-21x PLC's typically used on Autocaster Basic and old Batchmasters. |