How Do I Control The Resin Temperature On My Autocaster? |
|
|
|
|
Tuesday, 12 February 2013 00:07 |
|
To make sure you are getting good temperature control use the following guidelines.
Set the dial for the manual heater temperature safety limit to 150 – 180 °F (65.5 - 82.2 °C)
Set the temperature control points on the setup screen.
Set the RUN mode Resin temperature to the desired resin temp. Typically 90 – 110 °F (32 - 43.3 °C)
Set the Run Mode Maximum Fluid Temp to a point higher than the resin set temp to allow it to heat the resin. Typically 10-20 °F (-12.2 to -6.67 °C) above the resin set temp.
Set the Recirc Mode Resin temp to a reasonable good starting temperature. Typically 70 – 80 °F (21.1 - 26.7 °C)
Set the Recirc Mode Fluid Maximum Temperature to the same or slightly higher temperature as the resin recirc set temp. There is such a short loop for recirculation that it doesn’t take much to maintain a resin temperature during recirc. If you re-plumb the resin recirc to return to the tote instead of the pump to allow preheating of the tote the maximum fluid temp should be raised to about 5 – 15 °F (-15 to -9.4 °C) above the resin set temp.

|
|
|
Tuesday, 12 February 2013 00:00 |
|
This is our first syndicated RSS feed to the outside world. We're hoping to spread the word about how prospective cast polymer manufacturers worldwide can make money producing cultured marble, solid surface or other cast polymer products for homes, commercial, instituional bathrooms, kitchens and other applications.